  16.  Overview
  17. ----------
  18.  
  19.  The ScanTek scanner driver has the following features:
  20.  
  21.  1. Support of the following SCSI Microtek scanner models:
  22.         MICROTEK IISP, MICROTEK II, HIGHSCREEN Flatbed Color IIs,
  23.         ScanMaker E3, ScanMaker 35t, ScanMaker E6,
  24.         Highscreen PerfectScan, older Highscreen HighScan
  25.  
  26.         Microtek E3PLUS, V300, 330, 630 and new Highscreen HighScan
  27.  
  28.            This new scanner model can be used in black&white, grey scale
  29.            and color scanning.
  30.            The download of color lookup tables (gamma curves) is now
  31.            supported.
  32.            Color scan images can contain a shifted segment, if the image
  33.            data is written to a harddisk on the same SCSI host adapter.
  34.            The image data should be written to a harddisk on another SCSI
  35.            host adapter or to a IDE harddisk.
  36.  
  37.  
  38.     Support of the following SCSI Mustek Paragon scanner models:
  39.         Three Pass Scanners:
  40.         Paragon 6000CX, 8000CX (not tested), 12000CX all should work
  41.  
  42.         One or Single Pass Scanners:
  43.         Paragon 6000SP, 8000SP, 12000SP (now supported) all should work
  44.         Paragon 6000CZ, 8000CZ (not tested)
  45.  
  46.         Paragon 600IISP, 800IISP
  47.  
  48.  
  49.     The following scanner models are in the development phase:
  50.         Microtek ScanMaker 636, 336 and x6           
  51.           Scanned images of this models may contain strong color failures.
  52.           After the reception of the new Microtek programming documentation
  53.           this filaure can be resolved. A fast solution is possible.
  54.  
  55.  
  56.     The following scanner models are recognized but not fully supported: 
  57.         Mustek ScanExpress 12000SP
  58.         Mustek Paragon 1200IIISP (caution: III -> version 3)
  59.            Color scanning is only successfull at resolutions of 150, 300,
  60.            600 and 1200 dpi.
  61.            Grey scale scanning is possible.
  62.            If the image to be scanned exceeds the scan buffer size than
  63.            the image is corrupt. This effect is independent from the
  64.            scan mode.
  65.            The scanning quality is also (!) dependent from the used
  66.            SCSI host adapter.
  67.            The ScanExpress or Paragon 12000IIISP scanner models are
  68.            not recommended for ScanTek.
  69.            At least until sometimes in the future the corresponding
  70.            Mustek SCSI programming documentation for these new models
  71.            is available. I think this might be a Millenium projekt.
  72.  
  73.  
  74.     The following scanner models are not supported by now: 
  75.         All remaining Mustek ScanExpress and Paragon IIISP models.
  76.  
  77.  
  78.     The following scanner models are not supported:
  79.         Canon, Epson, HP, Umax and any parallelport scanner.
  80.  
  81.  
  82.     Attention: In recent times Mustek has changed the scanner firmware.
  83.                I urge you to test Mustek scanners with your Amiga
  84.                configuration before buying it.
  85.  
  86.                Mustek scanners have a critical SCSI interface. It
  87.                was reported to me that these scanners may not work
  88.                with the A2091 and A3000(T) internal SCSI interface.
  89.                It is possible that these scanners do not work with
  90.                other SCSI host adapters, either.
  91.                But the Mustek 6000CX and Paragon MFS-12000SP work in
  92.                combination with an Oktagon SCSI host adapter.
  93.                Be sure to disable reselection for Mustek scanners
  94.                on your SCSI host adapter. Otherwise your system may
  95.                not boot.
  96.  
  97.  2. Support of black/white, built-in halftone (dither), one-pass-color-scan,
  98.     three pass color scan, grey, red, green and blue scan.
  99.  
  100.  3. Individual setting of resolution, scanning frame, contrast, shadow,
  101.     midtone, highlight, exposure time and scanning speed for download to the
  102.     scanner.
  103.  
  104.  4. Download of a color look up table (gamma correction table ) to the scanner
  105.     supported.
  106.  
  107.  5. Scanning to IFF File of 1, 8 or 24 bit color depth. The maximum size of
  108.     the scanned image is independent from the RAM size. After the scanning
  109.     process it is possible to start an external program.
  110.  
  111.  6. GUI for preview and configuration of the driver. You need Kickstart 2.04
  112.     but Kickstart 3.0 is recommended.
  113.  
  114.  7. Sizeable preview window in black/white or grey scale. Color preview
  115.     on Cybergraphix screens (15, 16 or 24 bit necessary).
  116.     There are much more skilled programs to view and manipulate the scanned
  117.     images in color. (A tool like ADPRO, IMAGE FX or so is needed, if you
  118.     want to do sophisticated postproduction)
  119.  
  120.  8. ARexx support
  121.  
  122.  9. Screenmode requester to define custom screen for working. The actual public
  123.     screen is supported as well
  124.  
  125.  10. Configurable SCSI device and SCSI ID. The driver supports only SCSI
  126.      connectable scanners.
  127.  
  128.  11. The driver is tested with the following SCSI drivers: oktagon.device and
  129.      gvpscsi.device V4.5.
  130.  
  131.  12. ScanTek is written using SAS C 6.58.
  132.  
  133.  13. ScanTek is SHAREWARE.
  134.  
  135.  14. The non registered version of ScanTek is a full working version, but all
  136.      scanned images have black lines to motivate you to register.
  137.      Additionally the maximum size of the preview is restricted.
  138.  
  139.  
  140.  History
  141. ---------
  142.  
  143.  V4.4  3 February 1999
  144.  
  145.    - Better Surfsquirrel SCSI support. New Microtek scanner should work
  146.      now after activating the Surfsquirrel SCSI Workaround.
  147.      Other SCSI Hostdapter may work as well after activating this
  148.      Workaround.
  149.  
  150.  
  151.  V4.3  6 December 1998
  152.  
  153.    - Support of the transparency adapter and control of the scanning and
  154.      transparency medium lamp for Microtek 63x, 33x and compatible
  155.      Highscreen HighScan scanner models
  156.  
  157.  
  158.  V4.2  9 September 1998
  159.  
  160.    - Locale catalogs now updated correctly
  161.  
  162.    - No color failures if the LookUp tables are deactivted for
  163.      Microtek 630, 330 and new Highscan II models
  164.  
  165.  
  166.  V4.1 29 August 1998
  167.  
  168.    - Full support for Microtek 630, 330 and new Highscan II models
  169.      - Color LookUp tables now supported
  170.      - Faster preview for new generation of ScanMaker scanners
  171.  
  172.    - ScanTek support homepage has been moved to
  173.        http://www.users.odn.de/~odn05111/scantek.html
  174.  
  175.    - Enhanced screen mode handling on program startup
  176.  
  177.  
  178.  V4.0 19 June 1998
  179.  
  180.    - Localization of ScanTek. Supported locales: english, deutsch, dansk
  181.  
  182.    - New email address: scantek@gmx.de, wzoehner@gmx.de
  183.  
  184.  
  185.  V3.11 24 May 1998
  186.  
  187.    - Support of the new Highscreen HighScan II (Microtek) and
  188.      the new version of the Microtek E3Plus
  189.  
  190.  
  191.  V3.10 17 April 1998
  192.  
  193.    - First attempt to support the new Microtek 330 scanner model.
  194.      The scanning speed depends in a large degree on the SCSI host adapter.
  195.      This scanner model may lead to hang ups of the SCSI bus (computer
  196.      system) on critical SCSI devices.
  197.  
  198.  
  199.  V3.9  15 March 1998
  200.  
  201.    - Better support for Mustek ScanExpress 12000SP and the identical
  202.      international Mustek Paragon 1200 III SP.
  203.      This scanner model is not recommended for ScanTek.
  204.        Preview works now also on small preview windows.
  205.        Color scanning is only successful at resolutions of 150, 300,
  206.        600 and 1200 dpi.
  207.        Only small scanning images are successful. The automatic segment
  208.        scanning is not possible on this scanner model.
  209.  
  210.    - The new Microtek model ScanMaker E3PLUS is in the testing phase.
  211.      (see Overview for details)
  212.    
  213.    - Microtek V300, Microtek 330, Microtek 630
  214.        These scanner models are due to the documentation related to           
  215.        the Microtek E3PLUS. They should work in an equivalent way.
  216.  
  217.  
  218.  V3.8  23 February 1997
  219.  
  220.    - Bugfix of Mustek color scan process (Scrambled image data in
  221.      segment scanning)
  222.  
  223.    - Support of Transparency Adapter (Slide Kit Unit) enhanced
  224.  
  225.    - First attempt to support the new european Mustek
  226.      ScanExpress 12000SP and international Mustek Paragon 1200 III SP.
  227.      These scanners are assumed to be identical.
  228.      Due to missing Mustek programming documentation for the new firmware
  229.      there is only a limited support of these scanner models:
  230.        ... Gray scale scanning is supported.
  231.        ... Color scanning is incorrect and is therefore unusable
  232.      These scanner models are not recommended for the use with ScanTek.
  233.      If there will be a Mustek programming documentation some time in the
  234.      future than a second attempt for the support will be made.
  235.  
  236.  
  237.  V3.7  30 December 1997
  238.  
  239.    - Detection of Mustek scanners enhanced
  240.      Erkennung von Mustek Scannern weiterentwickelt
  241.  
  242.    - German Documentation
  243.      Deutsche Anleitung
  244.  
  245.  
  246.  V3.6  21 December 1997
  247.  
  248.    - The Mustek MFS-12000SP is now supported
  249.    - Rework of ASL requester handling
  250.    - PROGDIR: usage reduced
  251.  
  252.  
  253.  V3.5  4 December 1997
  254.  
  255.    - Rework of window activation procedures
  256.    - Rework of font sentivity
  257.    - PROGDIR: usage reduced
  258.    - Support of multiple SCSI host adapters in one system
  259.  
  260.  
  261.  V3.4  21 October 1997
  262.  
  263.    - Support of Transparency Adapter (Slide Kit Unit)
  264.    - Prevent system lockup during startup on Dataflyer SCSI+ host
  265.      adapter
  266.  
  267.  
  268.  V3.3   1 August 1997
  269.  
  270.    - Detection of ScanMaker35t+ introduced 
  271.    - Faster preview scanning process on some scanner models
  272.    - "Accurate Coordinates" support for ScanMaker E6 and compatible
  273.  
  274.  
  275.  V3.2   8 June 1997
  276.  
  277.    - Workaround for surfsquirrel.device to avoid SCSI bus hangup
  278.    - AREXX scripts: Load scanned pictures into 
  279.                     ImageFX:   ST2ImageFX.strx
  280.                     ArtEffect: ST2ArtEffect.strx
  281.  
  282.  
  283.  V3.1  19 May 1997
  284.  
  285.    - Recognition of Highscreen PerfectScan (600dpi) introduced
  286.    - Recognition of Highscreen RealScan (300dpi) introduced
  287.    - Activation of newly opened windows works now correct
  288.  
  289.  
  290.  V3.0   16 Apr. 1997
  291.  
  292.    - AREXX support
  293.    - XBMI-chunk introduced to store DPI (dots per inch) information in
  294.      IFF File
  295.    - Handling of Microtek ScanMaker E6 enhanced
  296.    - Bugfixes: "Exposure Time" and "Contrast" parameters for Microtek
  297.                and some Mustek scanner models are now correct.
  298.                This bug could lead to images that where to light.
  299.                Grey preview of color image now work with all specified
  300.                settings.
  301.  
  302.  
  303.  V2.10 26 Mar. 1997
  304.  
  305.    - Full size preview on 400 dpi Mustek scanners adjustable
  306.  
  307.  
  308.  V2.9   9 Feb. 1997
  309.  
  310.    - Look Up Table Window redesigned to ensure font sensitivity
  311.  
  312.  
  313.  V2.8  11 Jan. 1997
  314.  
  315.    - New icons for ScanTek
  316.    - Recognition and handling of new Mustek scanners enhanced
  317.    - Minior bug fixes
  318.    - Introduction of the ScanTek Support WebSite
  319.  
  320.  
  321.  V2.7  6 Dec. 1996
  322.  
  323.    - Recognition and handling of new Mustek scanners enhanced
  324.    - Recognition of Microtek ScanMaker E6 adapted
  325.  
  326.  
  327.  V2.6  30 Oct. 1996
  328.  
  329.    - Full support of Mustek one pass scanners
  330.    - Recognition of Mustek scanners enhanced
  331.  
  332.  
  333.  V2.5  5 Oct. 1996
  334.  
  335.    - Workaround to handle strange color mode behaviour of Mustek
  336.      one pass scanners
  337.    - Reverse scanning in black and white mode introduced
  338.  
  339.  
  340.  V2.4 10 Sept. 1996
  341.  
  342.    - Support of Mustek SCSI one pass color scanners in color mode and
  343.      parameter ranges.
  344.    - ScanTek can now open its GUI windows on the actual public screen.
  345.  
  346.  
  347.  V2.3  6 Sept. 1996
  348.  
  349.    - Color Preview on Cybergraphix screens in true color mode
  350.      (15, 16 or 24 bit) for onepass flatbed scanners
  351.    - Grey/Red/Green/Blue Preview on Cybergraphix screens in true color mode
  352.      (15, 16 or 24 bit) for threepass and onepass flatbed scanners
  353.    - Change and recall of predefined resolution values
  354.  
  355.  
  356.  V2.2 26 July 1996
  357.  
  358.    - Enhanced support for Mustek scanners
  359.      "Exposure Time" and "Contrast" parameters are now correct
  360.    - Gamma value "All" now works on threepass scanner
  361.    - Alternative Black/White scanning mode
  362.  
  363.  
  364.  V2.1  5 July 1996
  365.  
  366.    - Preview now fully supported for Mustek 6000CX
  367.    - Special adaption for Mustek 6000CX to use 8.5 * 14 inch scanning frame
  368.  
  369.  
  370.  V2.0  30 Apr. 1996
  371.  
  372.    - Preview in color mode with proper options values
  373.    - Use of expanded Contrast and Exposure Time selections on certain scanners
  374.    - X and Y Aspect Ratio in color images is correct now
  375.    - ScanMaker E3 does not support undocumentated red, gree and blue scanning
  376.    - Lookup Table command supported (Gamma Correction on certain scanner
  377.      possible)
  378.    - Scanning Frame Setting is now more intuitive
  379.    - Reverse image scanning supported (only on certain scanners possible)
  380.    - Accurate scanning supported. Scanning frame is now more precise.
  381.  
  382.  
  383.  V1.3  25 Feb. 1996
  384.  
  385.    - Detection of new ScanMaker E3 Flatbed scanner implemented
  386.    - Special adaption for E3 to use 8.5 * 13.5 inch scanning frame
  387.      (due to E3 inquiry data the max frame size is 8.5 * 11.69 inch)
  388.    - No start of the external program, if the scanning process is aborted
  389.    - Higher dpi rates for ScanMaker 35t (slide scanner) possible
  390.      Preview image should look better now.
  391.    - "Main Control" window and gadgets modified
  392.    - Debug filename "ScanTek.log" can be overriden through CLI or Tooltype
  393.  
  394.  
  395.  V1.2   3 Jan. 1996
  396.  
  397.    - Debug output data revised and enhanced
  398.    - Max Frame Setting setting introduced
  399.    - Start of external program possible
  400.    - Window positions are remembered and saved
  401.    - Configuration file enhanced
  402.  
  403.  
  404.  V1.1  17 Dec. 1995
  405.  
  406.    - detection of Microtek scanner via SCSI inquiry enhanced
  407.    - stepping of resolution slider adapted to expanded base resolution
  408.    - calculation of scanning frame size data modified
  409.  
  410.  
  411.  V1.0  30 Nov. 1995
  412.  
  413.    - first public release
  414.  
  415.